Add Formation Tops and bound a reservoir interval
WellSchema has no reservoir object. What it has is Formation Tops: a formation runs from one Formation Top down to the next, so two of them can bound the interval you mean.
By WellSchema Engineering ·
Add a Formation Top
- In the editor’s left panel, open Formations and choose Add Formation.
- Type its Name.
- Type Top. This depth is TVD, unlike the MD depths on the casing, Tubing and perforation forms. Rows put themselves in depth order when you leave the field.
- Choose its Lithology if you want the band textured. It starts on Default / Unspecified.
- Choose Save at the top of the editor.
The first Formation Top you add turns on the Formation Column, the banded column beside the drawing. To hide it or bring it back, use the Layer Visibility control on the drawing, and its Formation Column box.
Bound an interval with two Formation Tops
A formation runs from its Formation Top down to the next one by depth. The last one runs to the bottom of the drawing. So one Formation Top alone doesn’t end anywhere, and it takes a second to close the interval.
- Add a Formation Top at the top of the interval, and put what you need in its Name, such as the name of the reservoir. Give it the Lithology you want it to show.
- Add a second Formation Top at the base of the interval, named for what lies below it.
- The band between the two is your interval. Its label shows the name and depth of the upper Formation Top.
What the band will and won’t do
- A band too short to hold a label has none. A name longer than 20 characters is cut short on the label. Hover over the band for the full text.
- Nothing ties a perforation to a band. To say which formation a perforation is in, type it in the perforation’s Formation field. That field is free text and is not checked against your Formation Tops.
- A Formation Top below the bottom of the drawing isn’t drawn.
Or import your Formation Tops
Import, beside Add Formation, opens Import Formation Tops for a spreadsheet, CSV, text file or PDF. A photo is accepted where AI reading is available. For a spreadsheet, CSV or text file, it maps the columns, and if the file doesn’t state a depth’s unit or zero, it asks you to choose before Next step. It then shows every Formation Top for you to check before it lands.
If the schematic already holds Formation Tops, Import Mode starts on Replace, which removes them. Choose Add to keep them.
With Full Access, if WellSchema finds no table in the file, the file’s first rows go to an AI provider to find one, on their own, and the dialog says so before you pick a file. See Use AI reading: what leaves your computer and when. An EDM XML Export can bring Formation Tops across too.